Active Dynamic Plate

February 20, 2021 By SPINEMarketGroup

Active is Nexus’ dynamic cervical plate that can apply up to 2mm of compression per level. Super elastic nitinol applies an active compression load to the fusion mass. Easy to use instruments including the rigid locking screwdriver make the plate fast to place and lock confidently. As with all Nexus cervical plates they are sized smaller than standard cervical plates to … [Read more...] about Active Dynamic Plate

Atlantis Translational

February 20, 2021 By SPINEMarketGroup

The Atlantis Translational® Anterior Cervical Plate System is a ratcheting plate featuring segments that translate under compression, but maintain their position under tension. Test results demonstrated that the unidirectional plate had less motion in flexion-extension and maintained a more consistent graft load when compared to bidirectional design.1,2 These comparative study … [Read more...] about Atlantis Translational

AntCer II

February 20, 2021 By SPINEMarketGroup

Ant-Cer II is a dynamic cervical plate that features a segmented design and a controlled, one-way ratchet to deliver a constant axial load on the graft. As a result, this device successfully applies Wolff’s Law to promote bone remodeling.  Available in single-level and multilevel plate designs, Ant-Cer II features patented one-piece, zero … [Read more...] about AntCer II

DynaTran®

February 20, 2021 By SPINEMarketGroup

DynaTran® is an internally-dynamized anterior cervical plating system that is designed to allow axial settling while reducing the risk of plate impingement on adjacent discs. With an integrated one-step screw locking mechanism, DynaTran®maintains a low 2.5mm profile across the entire surface of the plate. The uniquely-shaped graft windows enable both graft and end plate … [Read more...] about DynaTran®

KINETIC-SL

February 20, 2021 By SPINEMarketGroup

The KINETIC-SL Dynamic Anterior Cervical Plate System is an innovatively designed plate that offers up to 2mm of dynamization per level.  The KINETIC-SL is a slim anterior cervical plate system with an integrated locking mechanism that allows bone screws to be securely fixated without any additional locking components.  The KINETIC-SL plate is internally dynamized and virtually … [Read more...] about KINETIC-SL

Mambo® modular cervical plate system

February 20, 2021 By SPINEMarketGroup

Mambo is a cervical plate system for anterior stabilization of the spine. The implant immobilizes the fusion mass until the implant of bone graft has fused.The main feature of the system makes it possible to choose dynamic or rigid instrumentation. Thanks to the modular design, the plates can be individually extended for multisegmental instrumentation.The integrated sliding … [Read more...] about Mambo® modular cervical plate system

PREMIER® Anterior Cervical Plate

February 20, 2021 By SPINEMarketGroup

The PREMIER® Anterior Cervical Plate System provides for axial load sharing via vertical screw translation along slots in the plate, while maintaining constrained fixation at the distal end of the construct, where loading is highest. The use of external graft pre-compression helps to secure the graft in an optimal position for healing. The internal pre-compression component … [Read more...] about PREMIER® Anterior Cervical Plate

Pyrenees Translational

February 20, 2021 By SPINEMarketGroup

Pyrenees Translational is characterized by a unidirectional ratchet mechanism at each level to allow for controlled settling of the patient’s anatomy. Featuring SMARTLock Technology, the system does not require an additional locking mechanism as each screw head forms an autogenic lock to the plate upon … [Read more...] about Pyrenees Translational

Rhausler Anterior Cervical Vertebrae Plate System

February 20, 2021 By SPINEMarketGroup

The Rhausler Anterior Cervical Vertebrae Plate System is intended for use in single and multi-level anterior cervical intravertebral internal stabilization and arthrodesis surgeries from C3 through C7. Surgical indications and techniques of augmentation of bony stabilization with anteriorplate and screw in the cervical spine have been the subject of multiple clinical … [Read more...] about Rhausler Anterior Cervical Vertebrae Plate System

UNIFY® anterior cervical plate system

February 20, 2021 By SPINEMarketGroup

The UNIFY® anterior cervical plate system incorporates internal dynamization and optimized compression to maximize the principles of Wolff’s Law and help promote fusion. The pre-assembled expanding screws can be quickly driven and securely locked using one instrument. Optimized Compression:Intraoperative compression of 1mm per level helps provide a precise fit, … [Read more...] about UNIFY® anterior cervical plate system

Vectra-T

February 20, 2021 By SPINEMarketGroup

VECTRA-T.SGT.Depuy Synthes.pdf Features: Plates– Integrated blocking mechanism– Prelordosed– Large graft visibility window– 19 mm wide and 2.5 mm thin– Titanium alloy plate (TAN)– Integral Elgiloy clips lock the screws to the plate Screws– Screws are color coded to identify function and diameter– Regular screw diameter 4.0 mm– Each screw type is also available with … [Read more...] about Vectra-T

WishBone Medical: STERILE SPINE™

February 11, 2021 By SPINEMarketGroup

The WishBone Medical STERILE SPINE™ Anterior Cervical Plate (ACP) System consists of a variety of bone plates and self-tapping bone screws (available in several diameters) composed of titanium alloy (Ti6Al-4V ELI).  Sterile Spine.Brochure-Wishbone.pdfSterile Spine.SGT-Wishbone-Medical.pdfWishbone VIDEO ANIMATION INTENDED USE: A bone screw locking … [Read more...] about WishBone Medical: STERILE SPINE™

Why have Zimmer Spun off its Spine Business? What could happen now?

February 8, 2021 By SPINEMarketGroup

Last week Zimmer Biomet announced its intention to spin off its Spine and dental businesses. According to Bryan Hanson, CEO of the company, the goal is to focus on high-growth and priority areas such as knees, hips, S.E.T. and CMFT, prioritize resources and simplify their operating models. From our point of view, this strategic action of focusing on the markets … [Read more...] about Why have Zimmer Spun off its Spine Business? What could happen now?

Idys™-ALIF

February 5, 2021 By SPINEMarketGroup

Idys™-ALIF is an implant developed to perform interbody fusions of the lumbar spine using an anterior approach.Idys™-ALIF cages and plates were designed in collaboration with surgeons, by an experienced development team in the field of spinal implants. The design team has worked to create a cage made of PEEK, as well as an anatomical ALIF plate to restore disc height and lumbar … [Read more...] about Idys™-ALIF

STALIF M-Ti

February 5, 2021 By SPINEMarketGroup

MIDLINE II-Ti

Sixth generation STALIF® technology, STALIF M-Ti incorporates a novel, circumferential, titanium-coated, PEEK Integrated Interbody™ design that is raising the Gold Standard of lumbar interbody fusion. Benefits: Optimized Surface Technology: The Ti-ACTIVE™ coating provides a three-dimensional texturized surface that is microporous with hydrophilic properties, to facilitate … [Read more...] about STALIF M-Ti

Aries-L

January 15, 2021 By SPINEMarketGroup

ARIES-L

The Aries-L interbody fusion device features a proprietary multi-axis mesh and optimized micro-surface topology, both of which are designed to facilitate fusion. The product’s lattice helps increase the implant’s porosity to 80%, which provides unparalleled in-situ radiovisibility compared with other titanium implants. The implant’s anatomic profile, anti-migrational teeth, and … [Read more...] about Aries-L

TASMIN®R

January 12, 2021 By SPINEMarketGroup

Minimal Access – Maximal Effect Posterior lumbar interbody fusion (PLIF) is today the gold standard in the treatment of degenerative disc disease. Most recently, surgical restoration of the sagittal and coronal profile in particular has gained in importance. Whilst physiological curvature of the spine allows for even load distribution, degenerative processes may result in … [Read more...] about TASMIN®R

TETRIS II

January 11, 2021 By SPINEMarketGroup

Two implants – One reliable treatment Posterior lumbar interbody fusion (PLIF) is today the gold standard in the treatment of degenerative disc disease. The TETRISTM Lumbar Fusion Implant System is designed to provide the surgeon with an optimal method for achieving immediate and long-term biomechanical stabilization and restoration of lordosis in the lumbar spine (L1 to … [Read more...] about TETRIS II

Vertelift-C Anterior Cervical Corpectomy Cage

January 11, 2021 By SPINEMarketGroup

Allowing a complete contact with vertebral surfaceProvide a secure fixation with the feature of threaded surfaceEfficient grafting space before distractionProvide one stage locking mechanism About Normmed Normmed makes a difference in both domestic and international markets with innovative solutions in its field and progresses on this path. Normmed, which manufactures … [Read more...] about Vertelift-C Anterior Cervical Corpectomy Cage

  • « Go to Previous Page
  • Page 1
  • Interim pages omitted …
  • Page 78
  • Page 79
  • Page 80
  • Page 81
  • Page 82
  • Interim pages omitted …
  • Page 170
  • Go to Next Page »

Primary Sidebar

PLATINUM SPONSORS

EXALTA 2LOGO-min
GLOBAL biomedica
NORMED newLOGO-min
GENESYS SPINE
SPINEGUARD2025
Dymicron 2
GSMEDICAL2025
spinewaygroup
RUTHLESS SPINE
RUDISHAUER
NGMEDICAL
LfC
ispine
CENTINEL SPINE
TSUNAMI MEDICAL
syntropiq logo
A-SPINE
L&Kmodelo log

POPULAR POST LAST 90 DAYS

  • Is DePuy Back in the Spine Fight? Why DePuy Really…
  • BROCHURES
  • What Globus Medical Really Bought With Higgs Boson Health
  • Globus Medical Announces Acquisition of Higgs Boson…
  • Highridge Medical CEO Departure: Spine’s…
  • DePuy Synthes for Sale: Who Could Actually Buy the…
  • Thinking About a Spine Robot? Your 2026 Guide to the…
  • Are Pedicle Screw Lawsuits Becoming a…
  • Strong Surgery, Soft Quarter: ATEC and the Cost of…
  • (UPDATED 2025): 6 Artificial Cervical Discs You’ll…
  • COMPANIES
  • The Giant Next Door: Is Mindray Spine’s Next…
  • DePuy Synthes Acquires Expanding Innovations™
  • Globus Medical Reports Second Quarter 2026 Results
  • (2025 Update): Market, Leading FDA-Approved Devices,…
  • Forty Cervical Discs, One 3% Market: The Fight to…
  • (UPDATED 2026) More Than 100 Options, No Single…
  • CD HORIZON® SOLERA™ System
  • Who Is PAULA, and Why Should Every Deformity Surgeon…
  • Johnson & Johnson Explores Potential $20B Sale…
  • Orthopedics Is Moving Into Pain. Zimmer and Globus…
  • Globus Medical: Stronger in Spine, but Could DePuy…
  • Percutaneous MIS Spine Systems: Why Adoption Still…
  • ProFlex Spine: Can a Nitinol Implant Crack…
  • L&K Spine Performs First U.S. Deformity Case…
  • CarboFix Spine Launches CarboClear® Hybrid MIS…
  • Top Expandable Cages of 2025: Which Lumbar Implants…
  • Orthofix Discontinues M6-C™ and M6-L™ Artificial…
  • Managing Early-Onset Scoliosis: Which…
  • Xenix Medical Announces FDA Clearance and Full…
  • LAST 5 VIDEOS PUBLISHED

    1. Xenix Medical: Riva Modular Fixation System
    2. Spinal Elements: Overwatch® PCF
    3. Mighty Oak: Acorn 3D™
    4. Syntropiq: Lyra
    5. ATEC Spine: SafeOp®

    Footer

    Contact us:

    spinemarketgroup@gmail.com info@thespinemarketgroup.com

    • LinkedIn
    • Twitter
    • YouTube

    PRIVACY POLICY

    • Legal
    • PRODUCT LIBRARY

    Copyright © 2026 · SPINEMarketGroup