• Skip to main content
  • Skip to secondary menu
  • Skip to primary sidebar
  • Skip to footer
  • MANUFACTURERS
  • HEADHUNTERS
  • COMPANIES

SPINEMarketGroup

Spine Industry News

  • HOME
  • 2026
  • 2025
  • 2024
  • BROCHURES
  • ARTICLES
  • PRODUCT LIBRARY

Roi-C

April 18, 2014 By SPINEMarketGroup

www.thespinemarketgroup.com
ROI-C

ROI-C® is a novel system designed for zero-profile, stand-alone* anterior cervical interbody fusion. The ROI-C Cervical Cage is available in a variety of profiles, heights, and footprints designed to match the patient’s anatomy and provide initial and long-term stability. The cage accommodates integrated, self-guided, self-locking VerteBRIDGE® plating designed to provide stability with no instrumentation protruding anterior of the vertebral bodies.

The self-guided, curved VerteBRIDGE plates are delivered in the plane of the disc through a direct anterior approach, so that the surgery can be achieved with less exposure than may be required to implant a traditional cervical plate, or even contemporary stand-alone systems with screws that must be inserted at oblique and challenging angles.The system features thoughtfully designed instrumentation including an inserter that protects anatomical structures when placing the cage and VerteBRIDGE Plating.

  • ROIC® Cervical Cage.Brochure.pdf
  • Available in two designs:The two sagittal profiles are designed to respect the patient’s anatomy and allow close contact between the bone and the implant, and to provide restoration of both height and lordosis.
    • Anatomic – Designed with a superior surface that complements healthy endplate contour
    • Lordotic – Tapered profile for patients with non-concave, flattened endplates
  • Stable and modular: Large peripheral weight bearing area, serrated profile, and the implants’ shapes enhance primary stability via immediate loading.Available in multiple footprints and heights to fit diverse spine anatomy
  • Optimized, large, central graft chamber for autograft bone
  • Radiolucent PEEK cage delivered in sterile packaging for quality and traceability
  • Simplified operative procedure:Designed by and for spine surgeons resulting in simple and functional instrumentation for an anterior mini-open technique

VerteBRIDGE® Plating Technology

  • Novel stand-alone technology*
  • Zero-profile design with no hardware protruding anterior of the vertebral bodies
  • Self-locking plates designed for initial and long-term stability
  • Anterior mini-open technique for insertion in the transverse plane
  • Adjustable anterior-posterior placement prior to insertion of the plate
  • Self-guided, curved plates ease insertion
  • Inserter provides protection of vascular structures during plate placement

Related Posts:

  • ROI-A
  • ROI-C
  • Kentro SELF Standalone cage

Filed Under: NEWS

Primary Sidebar

PLATINUM SPONSORS

EXALTA 2LOGO-min
GLOBAL biomedica
NORMED newLOGO-min
GENESYS SPINE
SPINEGUARD2025
Dymicron 2
GSMEDICAL2025
spinewaygroup
RUTHLESS SPINE
RUDISHAUER
NGMEDICAL
LfC
ispine
CENTINEL SPINE
TSUNAMI MEDICAL
syntropiq logo
A-SPINE
L&Kmodelo log

POPULAR POST LAST 90 DAYS

  • Is DePuy Back in the Spine Fight? Why DePuy Really…
  • BROCHURES
  • Highridge Medical CEO Departure: Spine’s…
  • DePuy Synthes for Sale: Who Could Actually Buy the…
  • Thinking About a Spine Robot? Your 2026 Guide to the…
  • Are Pedicle Screw Lawsuits Becoming a…
  • (UPDATED 2025): 6 Artificial Cervical Discs You’ll…
  • Strong Surgery, Soft Quarter: ATEC and the Cost of…
  • COMPANIES
  • The Giant Next Door: Is Mindray Spine’s Next…
  • DePuy Synthes Acquires Expanding Innovations™
  • Globus Medical Reports Second Quarter 2026 Results
  • (2025 Update): Market, Leading FDA-Approved Devices,…
  • (UPDATED 2026) More Than 100 Options, No Single…
  • Forty Cervical Discs, One 3% Market: The Fight to…
  • Globus Medical: Stronger in Spine, but Could DePuy…
  • Who Is PAULA, and Why Should Every Deformity Surgeon…
  • Sublaminar Bands in Spine Surgery: Why This Small…
  • Johnson & Johnson Explores Potential $20B Sale…
  • Top 60+ Minimally Invasive Sacroiliac Joint Fusion…
  • Orthopedics Is Moving Into Pain. Zimmer and Globus…
  • Percutaneous MIS Spine Systems: Why Adoption Still…
  • ProFlex Spine: Can a Nitinol Implant Crack…
  • L&K Spine Performs First U.S. Deformity Case…
  • CD HORIZON® SOLERA™ System
  • CarboFix Spine Launches CarboClear® Hybrid MIS…
  • Top Expandable Cages of 2025: Which Lumbar Implants…
  • VB Spine Funds Landmark Research to Deliver the…
  • Orthofix Discontinues M6-C™ and M6-L™ Artificial…
  • Managing Early-Onset Scoliosis: Which…
  • LAST 5 VIDEOS PUBLISHED

    1. Spinal Elements: Overwatch® PCF
    2. Mighty Oak: Acorn 3D™
    3. Syntropiq: Lyra
    4. ATEC Spine: SafeOp®
    5. REACH Medical: Expandable PLIF/TLIF Cage

    Footer

    Contact us:

    spinemarketgroup@gmail.com info@thespinemarketgroup.com

    • LinkedIn
    • Twitter
    • YouTube

    PRIVACY POLICY

    • Legal
    • PRODUCT LIBRARY

    Copyright © 2026 · SPINEMarketGroup