• Skip to main content
  • Skip to secondary menu
  • Skip to primary sidebar
  • Skip to footer
  • MANUFACTURERS
  • HEADHUNTERS
  • PRODUCT LIBRARY
  • COMPANIES

SPINEMarketGroup

Spine Industry News

  • HOME
  • 2026
  • 2025
  • 2024
  • BROCHURES
  • ARTICLES

ShurFit® LLIF Interbody Cage

January 1, 2018 By SPINEMarketGroup

The ShurFit® LLIF Interbody Cage is a minimally invasive, self-distracting vertebral body replacement system featuring a complete line of disc prep instruments and multiple retraction options that allow for optimal access and unrestricted visibility. The PEEK interbody design provides five footprints with a 7° lordotic angle to assist in reproducing the patient’s sagittal profile while providing anterior column support. The LLIF Cage incorporates an aggressive tooth pattern and a central strut to provide an overall stable platform, and the large graft windows allow for maximum biological coverage area for fusion.

  • ShurFit with MD-Vue distractor VIDEO ANIMATION
  • MD-Vue-Precision Spine.pdf
  • MD-Vue-STG.Precision-Spine.pdf

Features:

  • Large Graft Window optimizes biological ingrowth
  • Central Strut provides a stable platform
  • Self-distracting Bulleted Leading Edge allows for easy insertion

Distractor:

The MD-Vue™ Lateral Access System was designed in collaboration with top lateral spine surgeons and represents many years of lateral procedure experience. MD-Vue is the only lateral retractor that offers a unique and patented Nested 3-Blade Design which prevents blade creep during insertion. MD-Vue also incorporates a larger blade diameter, for increased surface area contact, which minimizes the pressure on neural structures during retraction. In addition, MD-Vue features an industry leading integrated, adjustable dual light source, as well as infinite retraction resolution and an improved rotary retraction mechanism that provides better control and tactile feel during retraction.

Features:

  • Large Blade Diameter increases surface area to minimize pressure on nerve root during retraction
  • Radiolucent Retractor increases visibility of critical anatomical structures during intraoperative C-Arm use
  • Patented Nested 3-Blade Interlocking Blade Design prevents blade creep during insertion (U.S. Patent Nos. 8,986,344; 9,414,831)
  • Optional 4th Blade Anterior Retraction enables surgeon to increase retraction field if necessary
  • Infinite Cranial/Caudal Resolution prevents unwanted nerve pressure by permitting surgeon to dial in precisely the desired amount of retraction versus traditional incremental step retraction

About Precision Spine

Precision Spine® is dedicated to providing quality products to hospitals, orthopedic surgeons, neurosurgeons and insurance companies. As a Made in the USA manufacturer and global distributor of spinal products, we have a comprehensive product portfolio that offers surgeons the intraoperative options and flexibility demanded by today’s challenging surgical procedures. And we continually strive to develop, engineer and distribute products that represent advanced treatment options.

Precision Spine takes pride in its ISO Certified, Made in the USA manufacturing operation. Additionally, we have recognized and implemented AdvaMed’s Code of Ethics into our workforce, as we feel adherence to ethical standards and compliance with applicable laws is critical to the medical device industry.

Precision Spine is a privately held company headquartered in Parsippany, New Jersey, with manufacturing facilities in Mississippi. https://www.precisionspineinc.com

Filed Under: Lateral Lumbar Interbody Fusion Cages Tagged With: LLIF

Primary Sidebar

PLATINUM SPONSORS

EXALTA 2LOGO-min
GLOBAL biomedica
NORMMED
GENESYS SPINE
SPINEGUARD2025
Dymicron 2
GSMEDICAL2025
spinewaygroup
RUTHLESS SPINE
RUDISHAUER
NGMEDICAL
LfC
ispine
CENTINEL SPINE
TSUNAMI MEDICAL
syntropiq logo
A-SPINE
logo paradigm spine

POPULAR POST LAST 90 DAYS

  • DePuy Synthes for Sale: Who Could Actually Buy the…
  • BROCHURES
  • PRODUCT LIBRARY
  • Expandable cages were adopted not because they fused…
  • Medical Device Correction Addresses Loss of Lordosis…
  • Who Is Really Winning the Mid-Tier Spine…
  • Medtronic Named in Florida Lawsuit Over Alleged…
  • Globus Medical’s Strategy: Building a Closed-Loop…
  • (UPDATED 2026) More Than 100 Options, No Single…
  • (2025 Update): Market, Leading FDA-Approved Devices,…
  • Johnson & Johnson Explores Potential $20B Sale…
  • Medtronic receives FDA clearance for Stealth AXiS™…
  • Why Expandable Cages Sometimes Lose Lordosis After…
  • Seven Leading Augmented (AR) and Extended Reality…
  • (UPDATED 2025): 6 Artificial Cervical Discs You’ll…
  • COMPANIES
  • 2025 Spine Product Launches and Trends: Where is the…
  • Medtronic Korea Launches Kanghui, a New…
  • Globus Medical Reports Fourth Quarter and Full Year…
  • Globus Medical Reports Preliminary Record Fourth…
  • Most Spine Failures Are Predictable — The Bone…
  • ATEC Announces Select Preliminary Financial Results…
  • Behind the Deal: The Strategic Logic of Zavation’s…
  • VB Spine to Acquire Intraoperative Visualization…
  • Johnson & Johnson Follows in Zimmer Biomet’s…
  • Australia’s Spine Market 2026: Growth, Top Local…
  • Orthofix Discontinues M6-C™ and M6-L™ Artificial…
  • From Niche to Momentum: The Rapid Rise of Spinal…
  • From Early Innovations to Modern Practice: Where Are…
  • Loyalty in the Spine Industry: Real, Valuable… and…
  • LAST 5 VIDEOS PUBLISHED

    1. SI-BONE: iFuse INTRA Ti™ Implant System
    2. Globus Medical: IntraLIF™ Cannulated
    3. SI-BONE: iFuse TORQ TNT® Implant System
    4. Globus Medical: VICTORY™ Lumbar Plate
    5. Alphatec Spine: ASCEND™ VBR 12mm

    Footer

    Contact us:

    spinemarketgroup@gmail.com info@thespinemarketgroup.com

    • LinkedIn
    • Twitter
    • YouTube

    PRIVACY POLICY

    • Legal

    Copyright © 2026 · SPINEMarketGroup