July 11, 2016 By SPINEMarketGroup

Intersomatic fusion via the transforaminal approach TLIF (transforaminal lumbar interbody fusion) is largely consistent with the principle of PLIF (posterior lumbar interbody fusion). The transforaminal approach (TLIF) requires unilateral resection of the joint. This enables convenient access to the disc space while also preserving the contralateral lamina and facet joint as an additional fusion surface. VERTACONNECT  is a cage for implanting into the prepared disc space of the lumbar spine. It is characterised by stable contact areas, toothed surfaces and a large fenestration for easy filling with bone material. The open design of the implant encourages the growth of bone into the disc space. The spreading at the ventral part of the VERTACONNECT implant enables the restoration of the sagittal alignment with a simultaneously minimal approach preparation.

VERTACONNECT is placed by a TLIF (transforaminal lumbar interbody fusion) approach in the L1–S1 spinal region. As well as the simple implantation procedure, the area of contact with the implant and the filling volume can be maximised by utilising the entire diagonal diameter of the vertebral body. The open design of the implant permits the cage to be packed with natural or synthetic bone graft substitute such as KAINOS® Inject. The inserted cage, combined with additional posterior instrumentation, leads to immediate biomechanical stabilisation. This establishes the ideal conditions for vertebral body fusion. The large range of implants provides for a high degree of intraoperative flexibility and ensures the restoration of the intervertebral space.

Product Advantages:

  • Expandable cage until 14° lordosis
    • Adapts optimally to the individual anatomy of the patient
    • Enables easy insertion due to low entry height
  • Diagonal implant placement
    • Easy and rapid implantation in a single surgical step
    • No complicated turning of the implant as needed for banana-shaped cages
  • Biconvex design with toothed surface
    • Anatomical adaptation in the intervertebral space
    • Optimal restoration of the sagittal alignment
  • Open Implant Design
    • Can be packed with natural or synthetic bone graft substitute
    • Promotes osseointegration
  • Toothed Surface
    • Secure anchoring in the bone thanks to high primary stability
    • Reduced risk of implant migration
  • Easy to use
  • Large Contact area with the vertebral body
    • Secure implant positioning
    • Reduced risk of subsidence

About SIGNUS

SIGNUS – the Sign for Spine: Passionate! Dynamic! Worldwide!

Innovative high-end implants made in Germany: For more than 25 years, SIGNUS has been the experienced specialist for comprehensive solutions in the surgical spine care sector. Founded in 1994 in Germany’s Lower Franconian city of Alzenau by Susanne and Uwe Siedler, our family-owned company currently has staff of approx. 80 at sites in Germany and Australia. SIGNUS offers the comprehensive product range of cervical spine to SIG sacroiliac joints, which are predominately manufactured at the nearby production site of ProCon Medizintechnik. In addition to Europe (CE) and the USA (FDA), we sell our certified implants throughout the world on every continent. Target-oriented further development of the products in connection with the continuous exchange with the users as well as international further education and hospitalisation programs make SIGNUS a reliable global partner.

The entire SIGNUS Portfolio with detailed information and descriptions are available for you online at www.signus.com

Filed Under: PLIF/TLIF Expandable Cages

Primary Sidebar

PLATINUM SPONSORS

EXALTA 2LOGO-min
GLOBAL biomedica
NORMMED
GENESYS SPINE
SPINEGUARD2025
Dymicron 2
GSMEDICAL2025
spinewaygroup
RUTHLESS SPINE
RUDISHAUER
CENTINEL SPINE
logo paradigm spine
LfC
NGMEDICAL
syntropiq logo
ispine

POPULAR POST LAST 90 DAYS

  • BROCHURES
  • PRODUCT LIBRARY
  • Can a Spine Sales Rep Be as Crucial as the Implant Itself?
  • 2025 Spine Product Launches and Trends: Where is the…
  • Did Globus Medical’s Q3 Performance Reinforce Market…
  • (UPDATED 2025): 6 Artificial Cervical Discs You’ll…
  • (2025 Update): Market, Leading FDA-Approved Devices,…
  • Johnson & Johnson Follows in Zimmer Biomet’s…
  • (UPDATED 2026) More Than 100 Options, No Single…
  • 2025 Update: Posterior Cervical Spine Systems Market…
  • COMPANIES
  • Medtronic Named in Florida Lawsuit Over Alleged…
  • First CD Horizon™ ModuLeX™ Deformity Surgery in…
  • Top Six Spine Industry Milestones in 2025
  • Globus Medical Reports Preliminary Record Fourth…
  • Seven Leading Augmented (AR) and Extended Reality…
  • The End of an Era: The Former LDR Medical Site in…
  • ATEC Announces Select Preliminary Financial Results…
  • Scientists Develop AxioMed Spinal Disc Replacement…
  • Medtronic Korea Launches Kanghui, a New…
  • LAST 5 VIDEOS PUBLISHED

    1. Spineology: New OptiMesh HA Nano
    2. Taiwan OrthopedicBiotechnology:  Caduceus 
    3. Augmedics: Meet X2
    4. LEM Surgical: Dynamis NVIDIA Isaac Sim
    5. Globus Medical: ExcelsiusXR™

     

     

    Footer

    Contact us:

    spinemarketgroup@gmail.com info@thespinemarketgroup.com

    • LinkedIn
    • Twitter
    • YouTube

    PRIVACY POLICY

    • Legal

    Copyright © 2026 · SPINEMarketGroup