- STALIF C VIDEO ANIMATION (Centinel Spine Old Version)
- STALIF C-SGT VIDEO ANIMATION (Centinel Spine Old Version)
- Optimized Surface Technology with Ti-ACTIVE: The Ti-ACTIVE™ surface provides a three-dimensional texturized surface that is microporous with hydrophilic properties, to facilitate human mesenchymal stem cell (hMSC) attachment and proliferation as demonstrated by pre-clinical testing performed on representative PEEK coupons with Ti-ACTIVE surface.During manufacturing, commercially pure titanium (CP Ti) is applied to the PEEK cage by a plasma spray to create our Ti-ACTIVE devices. The unique CP Ti surface system utilizes a robotic applicator, enabling the creation of a high-quality, reproducible titanium surface.3 Ti-ACTIVE was tested for mechanical integrity and the results exceeded the FDA requirements for shear and tensile strength for metallic spray surfaces.
- Integrally PEEK: Blending the Benefits of Titanium and PEEK By preserving its PEEK roots, STALIF C-Ti™ exhibits a modulus of elasticity similar to bone. In doing so, the device presents a reduced risk of subsidence relative to all-titanium cages.5 Additionally, STALIF C-Ti™ continues to maintain the radiolucent advantage of PEEK.
- PEEK is less rigid than titanium. PEEK’s elastic modulus is closer to that of cortical bone (see chart above).4 Compared to all-titanium cages, PEEK cages have been shown to be six times less likely to experience subsidence.6
- Integrated Interbody-No Supplemental Fixation:STALIF C’s integrated cage and screw system is cleared for use without supplemental fixation, while the “No-Profile” design allows it to nest fully within the confines of the vertebral body—leaving the anatomy unchanged external to the interbody.
-
No-Profile®: Conforms to Patient Anatomy:The STALIF C® “No-Profile” design allows it to nest fully within the confines of the vertebral body, leaving the anatomy unchanged external to the interbody.
-
The Lag Effect:Compressive Fixation Ensures Graft and Endplate Contact:As the preferred design to ensure fixation in cancellous vertebral bone, cancellous screws—combined with our screw head design—produce a lag effect between the vertebral body and the implanted device. The lag effect provides constant compressive forces against the implant which results in a greater interface between the graft and the endplate to facilitate the fusion process.
-
Anti Back-Out® Screws:STALIF C® screws provide an added layer of security with an Anti Back-Out® (ABO®) titanium split-ring which first compresses and then deploys during insertion.
About Silony Spine
Silony Spine is disrupting the spinal surgery marketplace with compatible options for enabling technology systems. Check out our portfolio of precision tools and hardware that add significant value and freedom of choice.Website: https://www.silonyspine.com/
(Visited 287 times, 67 visits today)