• Skip to main content
  • Skip to secondary menu
  • Skip to primary sidebar
  • Skip to footer
  • MANUFACTURERS
  • HEADHUNTERS
  • PRODUCT LIBRARY
  • COMPANIES

SPINEMarketGroup

Spine Industry News

  • HOME
  • 2026
  • 2025
  • 2024
  • BROCHURES
  • ARTICLES

STALIF C-Ti™

July 18, 2016 By SPINEMarketGroup

STALIF C’s integrated cage and screw system is cleared for use without supplemental fixation, while the “No-Profile” design allows it to nest fully within the confines of the vertebral body—leaving the anatomy unchanged external to the interbody. STALIF C® is part of an “integrated” system of implants and instruments designed to create consistent clinical results and avoid more destructive multiple incision surgeries.Based on the successful STALIF C® device, STALIF C-Ti™ incorporates a novel, titanium-surfaced PEEK Integrated Interbody™ design that is raising the Gold Standard of cervical interbody.
  • STALIF C VIDEO ANIMATION (Centinel Spine Old Version)
  • STALIF C-SGT VIDEO ANIMATION (Centinel Spine Old Version)
Benefits:
  • Optimized Surface Technology with Ti-ACTIVE: The Ti-ACTIVE™ surface provides a three-dimensional texturized surface that is microporous with hydrophilic properties, to facilitate human mesenchymal stem cell (hMSC) attachment and proliferation as demonstrated by pre-clinical testing performed on representative PEEK coupons with Ti-ACTIVE surface.During manufacturing, commercially pure titanium (CP Ti) is applied to the PEEK cage by a plasma spray to create our Ti-ACTIVE devices. The unique CP Ti surface system utilizes a robotic applicator, enabling the creation of a high-quality, reproducible titanium surface.3 Ti-ACTIVE was tested for mechanical integrity and the results exceeded the FDA requirements for shear and tensile strength for metallic spray surfaces.
  • Integrally PEEK: Blending the Benefits of Titanium and PEEK By preserving its PEEK roots, STALIF C-Ti™ exhibits a modulus of elasticity similar to bone. In doing so, the device presents a reduced risk of subsidence relative to all-titanium cages.5 Additionally, STALIF C-Ti™ continues to maintain the radiolucent advantage of PEEK.
  • PEEK is less rigid than titanium. PEEK’s elastic modulus is closer to that of cortical bone (see chart above).4 Compared to all-titanium cages, PEEK cages have been shown to be six times less likely to experience subsidence.6
  • Integrated Interbody-No Supplemental Fixation:STALIF C’s integrated cage and screw system is cleared for use without supplemental fixation, while the “No-Profile” design allows it to nest fully within the confines of the vertebral body—leaving the anatomy unchanged external to the interbody.
  • No-Profile®: Conforms to Patient Anatomy:The STALIF C® “No-Profile” design allows it to nest fully within the confines of the vertebral body, leaving the anatomy unchanged external to the interbody.
  • The Lag Effect:Compressive Fixation Ensures Graft and Endplate Contact:As the preferred design to ensure fixation in cancellous vertebral bone, cancellous screws—combined with our screw head design—produce a lag effect between the vertebral body and the implanted device. The lag effect provides constant compressive forces against the implant which results in a greater interface between the graft and the endplate to facilitate the fusion process.
  • Anti Back-Out® Screws:STALIF C® screws provide an added layer of security with an Anti Back-Out® (ABO®) titanium split-ring which first compresses and then deploys during insertion.

About Silony Spine

Silony Spine is disrupting the spinal surgery marketplace with compatible options for enabling technology systems. Check out our portfolio of precision tools and hardware that add significant value and freedom of choice.Website: https://www.silonyspine.com/

Filed Under: Anterior Cervical Interbody Cages (ACIF), Stand-Alone Tagged With: ACIF

Primary Sidebar

PLATINUM SPONSORS

EXALTA 2LOGO-min
GLOBAL biomedica
NORMMED
GENESYS SPINE
SPINEGUARD2025
Dymicron 2
GSMEDICAL2025
spinewaygroup
RUTHLESS SPINE
RUDISHAUER
NGMEDICAL
LfC
ispine
CENTINEL SPINE
logo paradigm spine
syntropiq logo

POPULAR POST LAST 90 DAYS

  • BROCHURES
  • PRODUCT LIBRARY
  • 2025 Spine Product Launches and Trends: Where is the…
  • Medical Device Correction Addresses Loss of Lordosis…
  • (UPDATED 2025): 6 Artificial Cervical Discs You’ll…
  • (2025 Update): Market, Leading FDA-Approved Devices,…
  • (UPDATED 2026) More Than 100 Options, No Single…
  • Medtronic Named in Florida Lawsuit Over Alleged…
  • Johnson & Johnson Follows in Zimmer Biomet’s…
  • 2025 Update: Posterior Cervical Spine Systems Market…
  • COMPANIES
  • First CD Horizon™ ModuLeX™ Deformity Surgery in…
  • Top Six Spine Industry Milestones in 2025
  • Globus Medical Reports Preliminary Record Fourth…
  • Seven Leading Augmented (AR) and Extended Reality…
  • The End of an Era: The Former LDR Medical Site in…
  • Medtronic Korea Launches Kanghui, a New…
  • Why Expandable Cages Sometimes Lose Lordosis After…
  • ATEC Announces Select Preliminary Financial Results…
  • Scientists Develop AxioMed Spinal Disc Replacement…
  • LAST 5 VIDEOS PUBLISHED

    1. REVEL™-S: Globus Medical
    2. EXCENDER CG Bio
    3. Spineology: New OptiMesh HA Nano
    4. Taiwan OrthopedicBiotechnology:  Caduceus 
    5. Augmedics: Meet X2

     

     

    Footer

    Contact us:

    spinemarketgroup@gmail.com info@thespinemarketgroup.com

    • LinkedIn
    • Twitter
    • YouTube

    PRIVACY POLICY

    • Legal

    Copyright © 2026 · SPINEMarketGroup